Re: SM30 : Conditionally Disable a column Cell

$
0
0

Hi Kripa,

 

Thanks for the reply. I did it like this..

 

MODULE edit_column_display OUTPUT.

  DATA : lv_line(48)  TYPE c,

         lv_field(18) TYPE c VALUE 'EXTRACT-LINE+23(1)'.

  FIELD-SYMBOLS: <fs_value> TYPE char1.

 

  ASSIGN (lv_field) TO <fs_value>.

*  IF sy-ucomm = 'CHECK'.

    "lv_line = ( 'EXTRACT-LINE' ).

    LOOP AT SCREEN.

      IF screen-name = 'ZTSD017_BILL_PLN-TO_DATE' AND

        <fs_value> = 'X'.

        "( 'EXTRACT-LINE+23(1)' ) = 'X'.

        screen-input = '0'.

      ELSE.

        screen-input = '1'.

      ENDIF.

      MODIFY SCREEN.

    ENDLOOP.

*  ENDIF.

ENDMODULE.